家

>

ブログ

>

AHU システムに適切なエア フィルターを選択する方法?

AHU システムに適切なエア フィルターを選択する方法?

目次

AHU エア ハンドリング ユニットとその濾過ステージとは何ですか

Customer Problem

Are your Air Handling Unit (アフー) operating costs skyrocketing while air quality downstream continues to deteriorate? Facilities management teams often notice rapid airflow reduction, high energy bills, and premature system cleanings. Selecting the wrong combination of air filters for an AHU system leads to unbalanced static pressure, frequent equipment downtime, and inadequate indoor air quality (IAQ) コンプライアンス.

AHU problems from wrong filter selection: high energy bills, low airflow, frequent cleaning, poor IAQ

Cause & Principle

Air filtration in an AHU works on the principle of gradient particle separation. Air contains particles ranging from visible dust (>10 μm) to microscopic airborne viruses (<0.3 μm). Attempting to catch all contaminants with a single, high-efficiency filter causes immediate surface loading, triggering an exponential rise in fan resistance. According to fan affinity laws, every additional 100 Pa of differential pressure forces the supply fan to consume significantly more kilowatt-hours to maintain designed CFM.

Airborne particle sizes from 100 micron down to 0.1 ミクロン

Comparison of Filter Stages

フィルタークラス 標準的な効率 Primary Role Common Form Factor
Primary (G1–G4 / Coarse)Traps particles >10 μm (花粉, 糸くず, 髪)Protects heating/cooling coils and secondary filtersSynthetic panel, pleated filter, air filter roll
Secondary (M5–F9 / ePM10, ePM1)Traps 1–10 μm fine dust, 煙, カビの胞子Protects ductwork, indoor occupants, およびHEPAフィルターポケット / bag filter, 硬質セルフィルター
Final / ヘパ (H10 ~ H14)Traps down to 0.3 μm at 99.97%+ 効率Delivers ultra-clean air for sensitive environmentsMini-pleat, deep-pleat HEPA box filter
Airy panel pre-filter range for the AHU intake stage
Airy pink pocket filter for the AHU secondary stage
Primary filters installed in an AHU with diamond grid support
Secondary pocket filters installed inside an AHU housing

How to Select

To build an optimal multi-stage configuration, match your facility’s requirements:

  • Standard Commercial Buildings (オフィス, Malls): 2-Stage System → G4 Panel Filter (プレフィルター) + F7 Pocket Filter (Secondary).
  • 産業 & Food Processing: 2 or 3-Stage System → G4 Pleated Filter + F8 Bag Filter + Optional Activated Carbon Stage (for odor/VOCs).
  • 医薬品 & Semiconductor Cleanrooms: 3-Stage System → G4 Panel + F9 Rigid Cell Filter + H13/H14 HEPA Filter.
Close-up of pleated carbon filter media
Close-up of hexagonal support mesh on filter media
Pleated pocket filters loaded in an AHU filter rack
Terminal HEPA box filter for the AHU final stage
Installed HEPA ceiling filter bank delivering clean air

Common Mistakes

  • Skipping the Pre-Filter: Installing an F7 or HEPA filter without a G4 pre-filter ruins the expensive fine filter within weeks.
  • Ignoring Total Cost of Ownership (TCO): Buying cheap filters with high initial resistance costs 3x to 5x more in electricity over the filter’s lifespan than investing in low-resistance media.
  • Changing Filters Only on a Fixed Calendar: Replacing filters on a rigid 6-month schedule instead of monitoring actual pressure differential (ΔP) leads to either wasted lifespan or severe fan overload.
Worker replacing a filter panel in an AHU access door

The Airy Solution

広州エアリーフィルターメディアCo., Ltd. manufactures low-resistance, high-dust-holding capacity media tailored for international AHU specifications:

  • Airy Progressive Density Media: Multi-layer synthetic structure that captures dust through the entire depth of the filter, lowering initial pressure drop by 15–20%.
  • Full-Range Matchability: From G1-G4 washables and roll media to F7-F9 ultrasonic pocket filters and H13 HEPA units, Airy provides a fully compatible one-stop supply chain.
Technician installing an AHU panel filter
Stacked pocket filters for AHU secondary filtration

よくある質問

How do I know when my AHU filters need replacement?

Always monitor the differential pressure gauge (例えば。, Magnehelic). Replace primary filters when initial pressure doubles, or when secondary filters reach their recommended final resistance (通常 250 Pa for bag filters).

Can Airy manufacture custom sizes for non-standard AHUs?

はい. Airy custom-cuts and fabricates metal frame panels, bag depths, and header dimensions to match OEM AHU tracks.

Optimize Your AHU Energy and Filter Life
Contact the Airy engineering team to receive a customized multi-stage filter selection guide and a factory-direct quotation.
View AHU Filter Products →
AHU エア ハンドリング ユニットとその濾過ステージとは何ですか

シルビア

創設者 & Industrial Filtration Strategist I founded Airy Filter in 2009, 持ってくる 14+ 産業用空気ろ過およびクリーンルーム ソリューションにおける長年の経験. 塗装ブース向けの高性能システムの提供を専門としています。, 製造, および管理された環境. BYDなどの大手クライアントをサポートしてきました。, 吉利, いすゞ, CRRC, 美的, と白雲山製薬, 地下鉄システムにまたがるプロジェクト, クリーンルーム, 国際インフラと, 発電所やグローバルサプライチェーンを含む. 実証済みのプロジェクト経験を持つ信頼できる濾過パートナーをお探しの場合, お気軽にお問い合わせください - 私のチームと私があなたのニーズをサポートする準備ができています.

連絡してください

*私たちはあなたの機密性を尊重し、すべての情報が保護されています.

人気のブログ

It seems we can't find what you're looking for.

whatsapp
×

今すぐカスタムエアフィルターの見積もりを入手してください!

産業用グレードのろ過または迅速なレトロフィットソリューションが必要かどうか, 操作を最適化するために、精密設計フィルターを提供します.

お問い合わせ

*私たちはあなたの秘密を尊重し、すべての情報が保護されます.